INVT GD20-1R5G-S2-EU

INVT GD20-1R5G-S2-EU
168 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the INVT GD20-1R5G-S2-EU and is the answer not in the manual?

INVT GD20-1R5G-S2-EU Specifications

General IconGeneral
ModelGD20-1R5G-S2-EU
Power Rating1.5 kW
Frequency Range0-400 Hz
Storage Temperature-20°C to +60°C
Humidity5% to 95% (non-condensing)
AltitudeUp to 1000 m without derating
Enclosure RatingIP20
SeriesGD20
Output Current7 A
Control MethodV/F control, Sensorless Vector Control (SVC)
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overtemperature, Short circuit
Communication InterfaceRS485, Modbus RTU
Cooling MethodFan Cooling
Operating Temperature-10 to 50 °C

Summary

Safety Precautions

Safety Guide

Provides general safety guidelines for operating the VFD and handling electrical hazards.

Product Overview

Rated Specifications

Lists models, voltage, power, current, and STO function ratings.

Installation Guide

Mechanical Installation

General instructions and guidelines for the mechanical installation of the VFD.

Standard Wiring

General guidelines and diagrams for standard wiring of the VFD.

Connection Diagram of Main Circuit

Wiring diagrams for the main circuit of different VFD types and models.

Terminals Figure of Main Circuit

Figures and descriptions of main circuit terminals for various VFD models.

Wiring Diagram of Control Circuit

Provides the wiring diagram for the VFD's control circuit connections.

Overview of STO Function

Explanation of the Safe Torque Off (STO) function, standards, logic, and delays.

Keypad Operation Procedure

Keypad Introduction

Introduction to the keypad and its buttons for VFD control and parameter adjustment.

Keypad Operation

Describes how to operate the VFD using the keypad and modify function codes.

Function Parameters

P02 Group Motor 1

Parameters for specifying motor characteristics like rated power, frequency, and current.

P03 Group Vector Control

Parameters related to vector control mode, including speed and current loops.

P04 Group SVPWM Control

Parameters for SVPWM control, including V/F curves, torque boost, and voltage limits.

P05 Group Input Terminals

Configuration parameters for various input terminals like HDI, AI1, AI2, AI3.

P06 Group Output Terminals

Selection parameters for digital and analog output terminals like Y1, RO1, RO2, AO1, AO2.

P14 Group Serial Communication

Parameters for serial communication setup, including Modbus protocol settings.

Fault Tracking

Fault Solution

General steps for troubleshooting VFD faults, including reset procedures.

Fault Instruction and Solution

Table of fault codes, types, possible causes, and recommended solutions.

Communication Protocol

Appendix A Technical Data

Appendix C Peripheral Options and Parts

Related product manuals