Goodrive300 Series VFD    Basic operation instruction 
171 
VFD is the upper limit frequency.   
Lower-limit frequency arrival 
Output ON signal when the running frequency of the 
VFD is the lower limit frequency. 
When  the  main  circuit  and  the  control  circuit  is 
established and the protection function of the VFD is 
not active. The VFD is in the running state and it will 
output ON signal.   
Output ON signal when the VFD is in the pre-exciting 
state.   
Output ON signal if the VFD is beyond the pre-alarm 
point.  Refer  to  P11.08–P11.10  for  the  detailed 
instruction.   
Output ON signal if the VFD is beyond the pre-alarm 
point.  Refer  to  P11.11–P11.12  for  the  detailed 
instruction.   
Simple PLC stage 
completion   
Output signal if the simple PLC stage is completed.   
  Simple PLC cycle 
completion 
Output signal if the simple PLC cycle is completed. 
Output ON  signal  if  the  detected counting  exceeds 
the set value of P08.25. 
Output ON  signal  if  the  detected counting  exceeds 
the set value of P08.26. 
Output ON signal if external fault occurs.   
Output  ON  signal  if  the  actual  detected  length 
exceeds the set length by P08.19. 
Output ON signal if the accumulative running time of 
the VFD exceeds the setting time by P08.27. 
Modbus communication 
virtual terminal output 
Output corresponding signal according to the setting 
value  of  Modbus.  Output  ON  signal  if  the  setting 
value is 1 and output OFF signal if the setting value 
is 0. 
POROFIBUS communication 
virtual terminal output 
Output a  corresponding  signal  according to the set 
value of PROFIBUS/CANOPEN. Output the signal of 
ON if the set value is 1 and output the signal of OFF 
if the set value is 0. 
Ethernet communication 
Virtual terminal output 
Output a corresponding  signal  according to the set 
value of Ethernet. Output the signal of ON if the set