Goodrive300 Series VFD Function parameters
89
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
fault
P07.55
Input terminals
state at last
but one fault
0
P07.56
Output
terminals state
at last but one
fault
0
P08 Group Enhanced function
P08.00
ACC time 2
See P00.11 and P00.12 for detailed definition.
Goodrive300 series define four groups of
ACC/DEC time which can be selected by P5
group. The first group of ACC/DEC time is the
factory default one.
Setting range: 0.03600.0s
Depend
on
model
P08.01
DEC time 2
Depend
on
model
P08.02
ACC time 3
Depend
on
model
P08.03
DEC time 3
Depend
on
model
P08.04
ACC time 4
Depend
on
model
P08.05
DEC time 4
Depend
on
model
P08.06
Jogging
frequency
This parameter is used to define the reference
frequency during jogging.
Setting range: 0.00 HzP00.03 (Max. frequency)
5.00Hz
P08.07
Jogging ACC
time
The jogging ACC time means the time needed if
the VFD runs from 0Hz to the Max. Frequency.
The jogging DEC time means the time needed if
the VFD goes from the Max. frequency (P00.03)
to 0Hz.
Setting range: 0.03600.0s
Depend
on
model
P08.08
Jogging DEC
time
Depend
on
model
P08.09
Jump
When the set frequency is in the range of jumping
0.00Hz

Table of Contents