Goodrive300-19 series open loop vector inverter special for hosit Function parameters
-72-
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
59: Brake feedback signal
60: Joystick zero position signal
61: Hierarchical reference terminal 1
62: Hierarchical reference terminal 2
63: Hierarchical reference terminal 3
64: Hierarchical reference terminal 4
65: Hierarchical reference terminal 5
P05.10
Polarity
selection of
input
terminals
The function code is used to set the polarity of input
terminals.
Set the bit to 0, the input terminal is anode.
Set the bit to 1, the input terminal is cathode.
BIT8
BIT7
BIT6
BIT5
HDI
S8
S7
S6
BIT4
BIT3
BIT2
BIT1
BIT0
S5
S4
S3
S2
S1
The setting range: 0x000~0x1FF
0x000
P05.11
ON-OFF
filter time
Set the sampling filter time of S1~S8 and HDI
terminals. If the interference is strong, increase the
parameter to avoid the disoperation.
The setting range: 0.000~1.000s
0.010s
P05.12
Virtual
terminals
setting
Enable the input function of virtual terminals at the
communication mode.
0: Virtual terminals are invalid
1: Modbus communication virtual terminals are valid
2~4: Reserved
0
P05.13
Terminals
control
running
mode
Set the operation mode of the terminals control
0: 2-wire control 1; the enabling and the direction
combine into one. This mode is widely used. It
determines the rotation direction by the defined FWD
and REV terminals command.
0