Goodrive300-19 series open loop vector inverter special for hosit Function parameters
-74-
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
stopping command from other sources, even the
control terminal FWD/REV keeps valid; the inverter
will not work when the stopping command is
canceled. Only when FWD/REV is relaunched, the
inverter can start again. For example, the valid
STOP/RST stop at terminal control (see P07.04).
P05.14
Switch-on
delay of S1
terminal
The function code defines the corresponding delay
time of electrical level of the programmable input
terminals from switching on to switching off.
Setting range: 0.000~50.000s
0.000s
P05.15
Switch-off
delay of S1
terminal
0.000s
P05.16
Switch-on
delay of S2
terminal
0.000s
P05.17
Switch-off
delay of S2
terminal
0.000s
P05.18
Switch-on
delay of S3
terminal
0.000s
P05.19
Switch-off
delay of S3
terminal
0.000s
P05.20
Switch-on
delay of S4
terminal
0.000s
P05.21
Switch-off
delay of S4
terminal
0.000s
P05.22
Switch-on
delay of S5
terminal
0.000s