Goodrive35 Series Closed-loop Vector Control VFD Function parameters
94
Functio
n code
Name
Detailed instruction of parameters
Default
value
Modif
y
1: Only / keys adjustment is valid
2: Only digital potentiometer adjustments is valid
3: Neither / keys nor digital potentiometer
adjustments are valid
LED tens: Frequency control selection
0: Only valid when P00.06=0 or P00.07=0
1: Valid for all frequency setting manner
2: Invalid for multi-step speed when multi-step speed
has the priority
LED hundreds: Action selection during stopping
0: Setting is valid
1: Valid during running, cleared after stopping
2: Valid during running, cleared after receiving the
stop command
LED thousands: / keys and digital
potentiometer integral function
0: The integral function is valid
1: The integral function is invalid
P08.43
Integral ratio of
keypad
potentiometer
0.0110.00 s
0.10
Hz/s
P08.44
UP/DOWN terminals
control
0x0000x221
LED ones: frequency control selection
0: UP/DOWN terminals setting valid
1: UP/DOWN terminals setting valid
LED tens: frequency control selection
0: Only valid when P00.06=0 or P00.07=0
1: All frequency means are valid
2: When the multi-step are priority, it is invalid to the
multi-step
LED hundreds: action selection when stop
0: Setting valid
1: Valid in the running, clear after stop
2: Valid in the running, clear after receiving the stop
commands
0x000