Goodrive35 Series Closed-loop Vector Control VFD Function parameters
121
Functio
n code
Name
Detailed instruction of parameters
Default
value
Modif
y
Range : -3000.0Nm3000.0 Nm
P17.37
PID deviation
-100.0%100.0%
0.0%
P17.38
PID output
200.00%200.00%
0.00%
P17.39
Wrong download of
parameters
0.0029.00
0.00
P18 States viewing 2
P18.00
Actual frequency
detected by the
encoder
P18.00 is the actual frequency of the encoder. If the
motor rotates forward, the value is positive; if the
motor rotates reverse, the value is negative.
Range: -3276.83276.7 Hz
0.0 Hz
P18.01
Position counting of
the encoder
Position counting of the encoder, 4 times of the
frequency
Range: 065535
0
P18.02
Pulse Z counting of
the encoder
Pulse Z counting of the encoder
Range: 065535
0
P18.03
MSB of the position
reference
The value will be cleared if stopping.
Range: 030000
0
P18.04
LSB of the position
reference
The value will be cleared if stopping.
Range: 065535
0
P18.05
MSB of the position
feedback
The value will be cleared if stopping.
Range: 030000
0
P18.06
LSB of the position
feedback
The value will be cleared if stopping.
Range: 065535
0
P18.07
Position deviation
The deviation between reference position and actual
operation position.
Range: -3276832767
0
P18.08
Position reference
The reference position of pulse Z when spindle
stops.
Range: 065535
0
P18.09
Current position of
the spindle
Current position setting when spindle stops.
Range: 0359.99
0.00
P18.10
Current position at
spindle orientation
Current position of the spindle at the oriented spindle
stop.
Range: 065535
0
P18.11
Reverse of pulse Z
Display of pulse Z direction. When the spindle stops,
the stopping position of forward and reverse rotation
may have a deviation of a few pulses. After adjusting
0