EasyManuals Logo
Home>INVT>DC Drives>Goodrive100-PV Series

INVT Goodrive100-PV Series User Manual

INVT Goodrive100-PV Series
89 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #25 background imageLoading...
Page #25 background image
Goodrive100-PV Series Solar Pumping VFD Function parameters
23
Function
code
Name
Detailed illustration of parameters
Default
Modify
includes: start, stop, forward/reverse
rotating, jogging and fault reset.
0: Keypad running command channel
(“LOCAL/REMOT” light off)
Carry out the command control by RUN,
STOP/RST on the keypad. Set the
multi-function key QUICK/JOG to
FWD/REV shifting function (P07.02=3) to
change the running direction; press RUN
and STOP/RST simultaneously in running
state to make the VFD coast to stop.
1: Terminal running command channel
(“LOCAL/REMOTflickering)
Carry out the running command control by
the forward rotation, reverse rotation and
forward jogging and reverse jogging of the
multi-function terminals.
2: Communication running command
channel (“LOCAL/REMOT” on);
The running command is controlled by the
upper monitor via communication.
P00.03
Max. output
frequency
This parameter is used to set the
maximum output frequency of the VFD.
Users need to pay attention to this
parameter because it is the foundation of
the frequency setting and the speed of
acceleration and deceleration.
Setting range: P00.04400.00Hz
50.00Hz

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the INVT Goodrive100-PV Series and is the answer not in the manual?

INVT Goodrive100-PV Series Specifications

General IconGeneral
BrandINVT
ModelGoodrive100-PV Series
CategoryDC Drives
LanguageEnglish

Related product manuals