Goodrive100-PV Series Solar Pumping VFD Function parameters
23
Function
code
Name
Detailed illustration of parameters
Default
Modify
includes: start, stop, forward/reverse
rotating, jogging and fault reset.
0: Keypad running command channel
(“LOCAL/REMOT” light off)
Carry out the command control by RUN,
STOP/RST on the keypad. Set the
multi-function key QUICK/JOG to
FWD/REV shifting function (P07.02=3) to
change the running direction; press RUN
and STOP/RST simultaneously in running
state to make the VFD coast to stop.
1: Terminal running command channel
(“LOCAL/REMOTflickering)
Carry out the running command control by
the forward rotation, reverse rotation and
forward jogging and reverse jogging of the
multi-function terminals.
2: Communication running command
channel (“LOCAL/REMOT” on);
The running command is controlled by the
upper monitor via communication.
P00.03
Max. output
frequency
This parameter is used to set the
maximum output frequency of the VFD.
Users need to pay attention to this
parameter because it is the foundation of
the frequency setting and the speed of
acceleration and deceleration.
Setting range: P00.04400.00Hz
50.00Hz