EasyManua.ls Logo

IONIC Zero PPM - Thermopure Heating System Faults

Default Icon
54 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Machine Operation
27
Thermopure™ Heating System
The heater unit has built in protection devices and will switch its self off if it detects a fault. If
the heater fails to start, first check the fuel level and battery condition, in the event that the
heater will not restart refer to Ionic Systems technical support.
The types of malfunctions are indicated by code flashing signals via the operation indicator
light during the after-run period of the heater.
After five short signals have been emitted, the long flashing pulses can be counted:
x1 No start ( After 2 start-up attempts)
x2 Flame extinction (recurrent >5)
x3 Under voltage or Over voltage
x4 Premature flame detection
x5 Flame detector interrupted or flame detector short circuit
x6 Temperature sensor interruption or temperature sensor short circuit
x7 Metering pump interrupted or metering pump short circuit
x8 Blower motor interrupted or blower motor short circuit or blower motor incorrect speed
x9 Pencil-type glow plug interruption or pencil-type glow plug short circuit
x10 Overheating