SUMMARY TABLE
MAINTENANCE OF THE DUAL POW ER - PETROL VERSION
IMPORTANT: these operations must be carried out with the machine o and the key removed.
All routine and corrective maintenance operations must be eected by competent personnel or at an authorised service centre.
As far as maintenance work on the engine is concerned, refer to the relevant handbook.
NOTE: the life of the battery strictly relates to regular periodic maintenance (checking the level and density of the electrolyte).
If the machine has not been used for a long time (for instance 4-6 weeks), it is in any case necessary to recharge the batteries to guarantee
that the voltage level never drops below the threshold value of 20.5 V.
If not used, batteries tend to lose their charge.
A : upon delivery
B : twice a week
C : every week
D : every 20 hours
E : every 50 hours
F : every 100 hours
G : every 150 hours
H :
every 300 hours
I : every 400 hours
CHECK
A B C D E F G H I
Battery liquid and voltage levels
Clean the engine air lter
Clean the panel lter
Oil and engine
Replace the engine oil
1
st
time
Check the brushes (or charcoal) of all electric motors and re-
place if worn
Tightness of the belts
Brake adjustment
Filter shaker
Tightness of the nuts and screws
State of the side brush
Tightness of the bin, lter, ap gaskets