EasyManua.ls Logo

IPC Eagle ct70 rider - Page 22

IPC Eagle ct70 rider
25 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ENGLISH
22
• the float switch has tripped (dirty
water drum), is clogged by dirt or
broken
empty the dirty water drum
or reset the float switch
• the suction hose is blocked • unblock the hose
the suction hose is not
connected to the squeegee or is
damaged
• connect or repair the hose
there is no power to the suction
motor or the motor is faulty
check that the motor power
connector is correctly
connected to the main wiring
and that the fuse is not
blown; in the second case
have the motor replaced
The machine does not move
the suction motor does not
operate
release the emergency
button; make sure the motor
is connected correctly to the
main wiring; check the type of
alarm present on the board
(see chapter 10); replace the
motor.
the motor thermal cutout has
tripped; the motor has
overheated
stop the machine, turn it off
and leave it to cool for at
least 45’
• the batteries are flat • recharge the batteries
The batteries do not provide
the normal work time
the battery poles and charging
terminals are dirty and oxidised
clean and grease the poles
and terminals, recharge the
batteries
• the electrolyte level is low top up all the elements with
distilled water as described in
the instructions
the battery charger does not
work or is unsuitable
see battery charger
instructions
there are considerable
differences in density between
the various elements of the
battery
• replace the damaged battery
you are using the machine with
excessive pressure on the
brushes
reduce pressure on the
brush
The battery discharges too fast
during use, even though it has
been charged correctly and
when tested with a hydrometer
at the end of recharging, it
turned out to be uniformly
charged
the battery is new and does not
deliver 100% of its expected
capacity
the battery must be "run-in"
by performing 20-30 charges
and discharges to obtain
maximum performance
the machine is being used at
maximum capacity for
continuous periods and the
working time is not sufficient
if possible, use batteries with
a higher capacity or replace
the batteries with others
charged previously
the electrolyte has evaporated
and does not cover the plates
completely
top up all elements with
distilled water until the plates
are covered then recharge
the battery