CONTROL PANEL FEATURES
Page 10
1. LED Multi-Meter: Displays voltage,power,fuel level,
frequency, and running time.
2. Low Idle Push Button: Low idle minimizes the fuel
consumption and noise by adjusting the engine speed
to the minimum required for the current load.
LED Data Center
5. Select Button: Push this button to show the volage,
power,fuel level ,frequency or total running time in LED
Multi-Meter.
3. Overload Reset Button with Indicator Light: The
indicator light is green when the inverter is running
under rated load. The indicator light will turn to blinking
red or solid red when the rated load is exceeded. When
the maximum load is reached, the inverter will automati-
cally cut off all AC outputs to protect the inverter. Press
the overload reset button to restore the power without
stopping the engine.
4. Oil Warning Indicator LED (Red): Illuminates when
the engine oil level falls below the safe operating level
and he generator will automatically shut off the engine.
The engine will not start until the proper amount of oil is
in the crankcase.
H
1.3
305.3
2 3 4 5
1