b. The ow switch must be installed for safety reasons to
prevent dosing chemicals when there is no ow in the
circulaon piping.
c. Prior to installaon, the controller operaon can be
tested by lng the populated mounng board unl the
controller’s green light turns on (ow switch magnet at the
switch’s top).
24
M820 pH/Dual ORP Controller Owner’s Manual
Figure 6: Hidden buon
7. Hidden Features
a. The Up/Down buons can be locked out to prevent
unauthorized changes to the sengs. There is a hidden
buon behind the “0” in IPS-M820 on the front overlay.
Place the M820 into standby mode and then press and
hold the hidden buon for 2 seconds, unl the display
indicates “Loc On” and the Up/Down keys do not operate.
All other feature buons will work to display current
sengs. Turn the lock o by holding the hidden buon
down for 2 seconds unl the display indicates “Loc O”.
b. The M820 can be forced to manually dose pH, ORP1, or
ORP2 by placing the M820 into the standby mode that
is desired (pH, ORP1, ORP2), and then holding down the
Dose Time buon and pressing the Delay Time buon. The
M820 will dose for the me set in the dose me seng
(med-feed only).