EasyManuals Logo

IPS Controllers M820 User Manual

IPS Controllers M820
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #29 background imageLoading...
Page #29 background image
28
M820 pH/Dual ORP Controller Owners Manual
IV. Troubleshoong
A. pH level too low or Alert Led On
1. pH Set level is too low: Check pH level with test kit and adjust
as necessary.
2. Chemical dose me too high: Lower dose me.
3. Chemical feeder is empty (base): Rell the feeder.
4. Sensor malfuncon: Replace sensor.
*Low alkalinity can also cause pH to dri to lower levels. Always
target 80-120ppm
B. pH level too high or Alert LED On
1. Sensor p is dirty: Clean according to maintenance
instrucons.
2. Improper pH sensor calibraon: Adjust pH calibraon.
3. Chemical feeder is empty (Acid): Rell the feeder.
4. Chemical feed pump or squeeze tube malfuncon: Repair the
feed pump or replace the squeeze tube. A squeeze tube will
last 3-6 months for commercial properes and 6-12 months for
residenal properes.
5. Chemical dose me too low: Increase dose me.
*High alkalinity will require more acid than usual to maintain pH
levels. Always target 80-120ppm
C. Chlorine/Bromine level too low or Alert LED On
1. pH should be at your desired set level before addressing any
potenal ORP problems.
2. ORP Set level is too low: Check Sanizer level with test kit and
adjust set Level as necessary

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IPS Controllers M820 and is the answer not in the manual?

IPS Controllers M820 Specifications

General IconGeneral
BrandIPS Controllers
ModelM820
CategoryController
LanguageEnglish

Related product manuals