EasyManuals Logo

IPS Controllers M820 User Manual

IPS Controllers M820
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #27 background imageLoading...
Page #27 background image
26
M820 pH/Dual ORP Controller Owners Manual
D. Maintenance
1. Winterizing (extended shutdowns or colder climates)
a. Turn o the M820 controller and shut o main power to
controller.
b. Gently remove the pH and ORP sensors from the ow
cell. Fill the provided protecve caps (removed during
installaon) with water and re-install onto each sensor, and
store in a warm, secure locaon. Sensor ends must remain
in water for the duraon of the storage me.
c. Drain the water from the ow cell.
2. Cleaning the sensor ps
Note: It is important to keep the sensor ps clean to ensure
accurate readings.
a. Sensor ps should be cleaned every 3 to 6 months for
commercial pools and spas, and every 6 to 9 months
for residenal pools and spas. Determine the necessary
frequency by comparing the readings before and aer the
cleaning. Idencal readings mean that the cleaning me
can be extended.
b. Turn o the M820 controller.
c. Close the right and le valves at the boom of the ow
cell.
d. Loosen the nut ng on the sensor and gently remove it
from the ow cell.
e. Swirl the sensor p in a soluon of liquid dish soap and
water for 30 seconds and rinse with water.
f. Swirl the sensor p for 5 seconds in Muriac acid or white
vinegar and rinse with water. Note: Do not touch or brush
the sensor p.
g. Gently re-insert the sensor into the ow cell and hand
ghten the nut ng.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IPS Controllers M820 and is the answer not in the manual?

IPS Controllers M820 Specifications

General IconGeneral
BrandIPS Controllers
ModelM820
CategoryController
LanguageEnglish

Related product manuals