DESCRIPTION
DISPLAYED
Code
ALS10 FULL MEMORY
The newly recorded item
cancels the last one on the list
Recording memory full
Slave-CPU NO
ALS11 Low voltage
Electronic card blockCard power supply
voltage less than 33%
Slave-CPU YES
ALM00 Loss of data
Loading of default data
Master NO
ALM01 Low voltage
Card power supply
voltage less than
Visual alarm only
Master NO
ALS13 Slave serial faulty
Block of cell card and
automatic reset
Failure in serial port of
the card
Slave-CPU YES
ALS14 Front serial faulty
Block of cell card and
automatic reset
Failure in serial port of
the card
Slave-CPU YES
ALS15 Defrosting timeout
The alarm is only recorded
in the record of alarms
The defrost cycle has
ended due to elapsed
safety time
Slave-CPU YES
ALS12 Thawing
The temperature of the
cell has risen above the
temperature set in
parameter 2-1 after the
time set in parameter 2-2.
In addition, the cell
temperature and defrost
probes are faulty
Slave-CPU YES
CAUSE EFFECT CARD
CYCLE
STOP
ALM02 Power outage
Automatic restart when
power comes back on
Master NO
ALM03
Master serial/external
Visual alarm only
Master NO
ALM04
Low voltage
Card power supply
voltage less than 33%
Electronic card block
Master YES
ALM05
Power outage
Master YES
ALM06 Thermal 1
Circuit breaker
compressor 1, open
Master YES
ALM07 Thermal 2
Circuit breaker
compressor 2, open
Master YES
ALM08 Thermal 3
Circuit breaker
compressor 3, open
Master YES
ALM09 Thermal 4
Circuit breaker
compressor 4, open
Master YES
ALM10 Press. Mech.
Activation of high
pressure switch
Cycle stop and automatic
restart when alarm ceases
Master YES
ALM11
Master/Slave
serial faulty
Failure of the serial
port for communications
between the cell card and
the condenser card
Block of condenser card
and automatic reset
Master YES