Do you have a question about the IrriGreen 2 and is the answer not in the manual?
| Communication | Wi-Fi |
|---|---|
| WaterSense Certified | Yes |
| Manufacturer | IrriGreen |
| Mobile App | Yes |
| Weather Adjustment | Yes |
Provides a link and password for an installation video guide.
Details the Wi-Fi/Cloud Controller and Digital Sprinkler units.
Covers cables, tees, transformer, and connectors for system setup.
Requires 1" mainline, elbows, and tees for connecting Flex-Pipe to mainline.
Includes two-conductor wire, grease caps/wire nuts, and small valve boxes.
Specifies required water pressure (40-80 psi) and flow rate (10+ gpm).
Addresses well systems and the need for filtration for particulate-laden water.
Details maximum and minimum throw distances (25'-35' max, 5' min) at various psi levels.
Notes that one head covers approximately 2000 sq. ft. at 60 psi.
Place heads to reach the farthest corner (25-35 ft), avoiding spray overlap.
Zone start-up point must be at least 10 ft for proper pop-up; can be adjusted later.
For narrow zones (<10 ft wide), place head along the edge with a ~180-degree pattern.
Program streams to hit individual bushes without drip irrigation.
Illustrates connections between controller, sensor, sprinklers, and mainline.
Shows controller cable, sprinkler cable, and flexpipe routing.
Digital sprinklers have zone numbers 1-8 and 9-16 assigned at the factory.
Place sprinklers in the numerical order desired for operation.
Position the sprinkler cap slightly above grade for optimal performance.
For slopes, install heads at approximately a ½ angle to the slope.
Attach Flex-Pipe to mainline/lateral piping using Teflon tape (2-3 layers).
Connect Genius Head to Flex-Pipe elbow using the supplied O-Ring, hand-tighten.
Flush lines before installing heads to remove dirt and sand.
Run sprinklers to remove all air from the system after installation to prevent errors.
Install the top bracket onto the wall using two screws.
Hang the controller onto the top bracket and secure the bottom with screws.
Details wiring of the flow sensor to the controller using red and black wires.
Shows plug-n-play cable connections from the controller to sprinklers.
Illustrates connection of the 24 VAC transformer to the controller.
Identifies terminals for Rain/Soil Sensor, Flow Sensor, Digital Sprinklers, and Master Valve.
Details terminals for Valve Zones 1-12 and Digital Sprinklers 9-16.
Details the power requirement of 24 VAC, 40 VA for the controller.
Illustrates the connection of the 24 VAC, 40 VA transformer to the controller.
Guides users to log onto the Irrigreen Wi-Fi network to start using the app.
Discusses factors affecting Wi-Fi range and the use of extenders.
The green button resets the system and requires holding for 2-3 seconds.
The blue button runs all zones and shuts down zones.
The red button connects the controller to the Wi-Fi router for connectivity.
Indicates system power when blinking, or Wi-Fi rollover status.
Indicates the system is currently watering.
Indicates a system error has occurred.
Connect up to eight digital sprinklers per run using sprinkler cables and tees.
Details how to seal the ending connection on the last sprinkler in line.
Wire controller cable to "iG 1-8" and "Common" for zones 1-8.
Avoid cutting/splicing, loop excess cable in valve boxes, protect connections.
Align arrows on connectors and push together until they bottom out.
Place CableLok top and bottom over connectors, aligning ridges, and snap into place.
All connections should be protected by a small valve box installed next to the digital head below turf.
Connect the red flow sensor lead to the "Flo1" terminal on the controller.
Connect the black flow sensor lead to the "Common" terminal on the controller.
Install with 24" PVC before and 12" after the sensor for optimal readings.
Install at a 45° angle to prevent air bubbles from causing flow errors.
Use waterproof "DBY" connections supplied for flow sensor and splices in valve box.
Push wire nut into gel cap ensuring wires are totally sealed by gel.
Wire one to "Common" and the other to "Valve 1-4" for drip/standard valves.
Wire one to "Common" and the other to "MV/P" for master valve or pump.
EcoZone systems relieve mainline pressure by opening a valve briefly after watering.
Connects the master valve to the "Common" and "MV/P" terminals.
Connect Normally Closed (NC) wires to "Sens1" and "Common" controller terminals.
Ensure green cap is tight and filter marks align with nozzle opening for proper stream.
Check and clean/change filter and nozzle if streams are not tracking evenly.
Avoid gluing sensor paddles to prevent inaccurate readings and calibration errors.
Seat sensor properly on the tee alignment pin when reassembling the impeller flow sensor.
Guides on checking wiring, zone activation, and replacing cables/sprinklers.
Steps to diagnose why the system doesn't detect a digital sprinkler.
Troubleshooting steps for when the flow sensor is not providing usable data.
Checks for flow sensor type, source flow/pressure, and sensor replacement.
Checks for debris, wiring, and tests with a new sprinkler for rotor issues.
Inspects for debris in ball valve, checks wiring, and tests with a new sprinkler.
Verifies controller power, Wi-Fi connection, server address, and power cycling.
States device complies with Part 15 of FCC Rules and operation conditions.
Warns against unauthorized modifications which void warranty and operating authority.
Loading...