14
True manual operation allows a single station to be
selected and run without regard to run time duration. Once
started, the station will run until it is turned off or the
controller clock time passes midnight.
1. Turn the control dial to Manual Station(s) position.
2. Press the button until the desired station number
is flashing and the display shows -- -- -- (dashes).
3.
Press the button once to activate the station. The
station number and ON will be displayed along with the
flashing watering
symbol . Leave the dial in the
Manual Station(s) pos
ition. The station will remain on
until operation is terminated or until midnight.
To terminate operation prior to midnight, turn the
control dial to any other position.
4
. Turn the control dial to Auto position when finished.
Timed manual operation enables any stations to be
given a temporary station run time duration and operated
in sequence.
1. Turn the control dial to Manual Station(s) position.
2. Press the
button until the desired station number
is flashing and the display shows -- -- -- (dashes).
3. Press the or button to select a temporary
station run time duration from 1 to 240 minutes.
Note: The temporary station run time will not affect
the station’s run time within any automatic program.
4. Press the
button to select the station.
5. Repeat steps 2–4 to select additional stations.
(These stations will not start immediately, but will
operate in sequence.)
6. After all desired stations for timed manual operation
have been selected, turn control dial to the Auto
position.
To manually advance through the station sequence,
press the button (the control dial must be in the
Auto position to use this feature).
To terminate the timed manual operation, either skip
through the remaining station sequence with the
button, or turn control dial to the Off position
for at least three seconds.
Manual program operation enables automatic watering
programs to be manually started and operated in
sequence.
1.
Turn the control dial to the Manual Programs
po
si
tion. The display will show MAN, the currently
selected program letter and stations assigned to the
program.
2. Press the button as needed to display a program
you wish to run. All stations which currently have a
station run time duration assigned to the selected
program will be shown at the top of the display.
3
. Press the button to start the program (or select an
additional program). The program letter and the
watering symbol
will begin flashing.
4. Repeat steps 2 and 3 to select additional programs to
operate in sequence.
5. Turn the control dial to the Auto position. The
remaining run time duration for the currently operating
station will be displayed. Station numbers and programs
waiting to run will also be shown.
Manual Program Operation
Timed Manual Operation
True Manual Operation

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Irritrol KwikDial and is the answer not in the manual?

Irritrol KwikDial Specifications

General IconGeneral
ModelKwikDial
MountingIndoor/Outdoor
Rain Sensor CompatibilityYes
Cycle and SoakYes
Rain Delay1 to 7 days
Manual WateringYes
Zones4, 6, 8, 12
Stations4, 6, 8, 12
Programs3 independent programs
Watering Schedule7-day calendar
Power Source120 VAC
Backup Battery9V battery
Watering Duration1 minute to 12 hours