Measurement Commands
Copyright© Itech Electronic Co., Ltd. 42
Chapter8 Measurement Commands
MEASure[:SCALar]:VOLTage[:DC]?
FETCh[:VOLTage][:DC]?
These two commands are used to read the output voltage of power supply.
Command syntax
MEASure[:SCALar]:VOLTage[:DC]?
FETCh[:VOLTage][:DC]?
Arguments
None
Returns
<NR2>
Unit
V
Example
MEAS:VOLT?
MEASure[:SCALar]:CURRent[:DC]?
FETCh:CURRent[:DC]?
These two commands are used to read the output current of power supply.
Command syntax
MEASure[:SCALar]:CURRent[:DC]?
FETCh:CURRent[:DC]?
Arguments
None
Returns
<NR2>
Unit
A