EasyManuals Logo

ITech IT6502D Programming Guide

ITech IT6502D
41 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #33 background imageLoading...
Page #33 background image
inquiry syntax[SOURce:]APPLy?
Return parameter<NRf>,<NRf>
4.7 Input Measuring Commands
MEASure[:SCALar]:VOLTage[:DC]?
This command is used to enquire the actual output voltage.
Command syntaxMEASure[:SCALar]:VOLTage[:DC]?
ParameterNone
Return parameter:〈NRf
Return parameters unitV
exampleMEAS:VOLT
FETCh:VOLTage?
This command is used to read the voltage to be handled in the sample cache. After sending
the command and let the instrument dialogue, the readings will be sent to the computer. This
command does not affect the instrument settings. This command does not trigger a
measurement operation, requires only the latest available reading. Before reading the new,
the command returns are old readings.
Command syntaxFETCh:VOLTage?
Return parameter<NRf>
Return parameters unitV
MEASure[:SCALar]:CURRent[:DC]?
This command is used to read the actual current.
Command syntaxMEASure[:SCALar]:CURRent[:DC]?
parameterNone
return parameter:〈NRf
return parameters unitA
exampleMEAS:CURR

Other manuals for ITech IT6502D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT6502D and is the answer not in the manual?

ITech IT6502D Specifications

General IconGeneral
BrandITech
ModelIT6502D
CategoryPower Supply
LanguageEnglish

Related product manuals