Command syntax[SOURce:]VOLTage:PROTection:CLEar
[SOURce:]VOLTage:LIMit[:LEVel]<voltage>
This command is used to set the lower limitation of output voltage
Command syntax[SOURce:]VOLTage:LIMit[:LEVel] <NRf>
parameterMIN TO MAX|MIN|MAX|DEF
unitV| mV| uV
inquiry syntax[SOURce:]VOLTage:LIMit[:LEVel]?
Return parameter<NRf>
[SOURce:]VOLTage:RANGe<voltage>
This command is used to set the upper limitation of output voltage
Command syntax[SOURce:]VOLTage:RANGe <NRf>
parameterMIN TO MAX|MIN|MAX|DEF
unitV |mV |uV
inquiry syntax[SOURce:]VOLTage:RANGe?
Return parameter<NRf>
4.6 Composite Control Command
[SOURce:]APPLy {<voltage>|MIN|MAX} [,{<current> |MIN|MAX}]
This command has combined two kinds of commands----VOLTage and CURRent.As long as
the setting value is within the range of max current and max voltage,then the output voltage
and current will execute according to the present setting value.APPLy command will only be
effective when the setting values are within the range of upper limitation.If not,an execution
error will occur.MIN and MAX can also be used as special parameters.Min will enable the
output voltage and current to be 0.Max will enable the output voltage and current to be the
upper limitation value.
Command syntax[SOURce:]APPLy <NRf>,<NRf>
parameterMIN~MAX
unitV, A