Return parameter:<NRf>
[SOURce:]VOLTage:PROTection:DELay
This command is used to set the software-voltage protection delay time.
Command syntax[SOURce:]VOLTage:PROTection:DELay<NRf>
parameter0.001~0.6
units
inquiry syntax[SOURce:]VOLTage:PROTection:DELay
Parameter0.001~0.6
Return parameter<NRf>
[SOURce:]VOLTage:PROTection:STATe
This command is used to set the software-voltage protection state.
Command syntax[SOURce:]VOLTage:PROTection:STATe<bool>
parameter0|1|ON|OFF
inquiry syntax[SOURce:]VOLTage:PROTection:STATe
parameterNone
return parameter0|1
[SOURce:]VOLTage:PROTection:TRIGgered?
This command is used to inquire the executing state of over voltage protection.If return
“1”,this indicates the OVP circuit has been triggered and the OVP state does not be cleared.If
return “0”,which means OVP circuit is not be triggered.
Command syntax[SOURce:]VOLTage:PROTection:TRIGgered?
Return value0|1
[SOURce:]VOLTage:PROTection:CLEar
This command is used to clear the OVP state.Before sending this command,please increase
the upper limitation of OVP or you can also reduce the output voltage.
Note:Please remove the external power supply which caused this protection and then send
this command.