SCPI Status Register
Copyright © Itech Electronic Co., Ltd. 12
Chapter2 SCPI Status Register
The IT6800A/B series power supply records the different status of the
instrument through the three status register group, the three status register
group are: standard event register, query status register and status bit enable
register. Status bit enable register records the information of the other
status register
Event Register Enable Register
VOLTAGE 0
CURRENT 1
not used Output Buffer
not used
TEMPERATURE 4
not used
not used
not used
not used
OVERVOLTAGE 9
OVERCURRENT 10
not used
not used Summary Register Enable Register
not used not used
not used not used
not used not used
STAT:QUES? STAT:QUES:ENAB<value> QUES 3
STAT:QUES:ENAB? MAV 4
ESB 5
RQS 6
OPER 7
Event Register Enable Register Serial Poll *SRE<value>
Operation Complete OPC 0 *STB? *SRE?
not used
Query Error QYE 2
Device Dependent Error DDE 3
Execution Error EXE 4
Command Error CME 5
not used
Power On PON 7
*ESR? *ESE<value>
*ESE?
Event Register Enable Register
CAL 0
ON/OFF 1
WTG 2
not used
not used
not used
not used
not used
Questionable Status
Standard Event
Status Byte
Operate Event
+
+
+
OR
OR
OR
+
OR
Event register is read only register, used to store the implementation status
of the power, the data used in the event register latches in the form, once
the data is stored, subsequent data will be completely ignored. Even

Table of Contents