Quick Start 
  Copyright ©  Itech Electronic Co., Ltd.  11 
 
2.  After  the  power  selftest,  VFD  displays  the  state  of  voltage  and  current  as 
below. 
 
 
 
 
Error Information References 
The following error information may occur when an error occurs during Power 
On self-test: 
  About 1second after power on, if the EEPROM was damaged, the VFD will 
display (about 1 S):   
 
 
 
  If  the  last  power  status  in  EEPROM  is  lost,  then  VFD  will  display 
information (about 1 S) as below:   
 
 
 
  If the calibration data in EEPROM is lost, then VFD will display (about 1S) 
as below: 
 
 
 
  If the factory calibration data in EEPROM is lost, and then the VFD will 
display(about 1 S) as below:   
  
 
 
Exception handling 
If the power supply cannot start normally, please check and take measures by 
reference to steps below. 
1.  Check whether the power line is correctly connected and confirm whether 
the power supply is powered. 
Correct wiring of power line => 2 
Incorrect  wiring  of  power  line  =>  Re-connect  the  power  line  and  check 
whether the exception is removed. 
2.  Check  whether  the  power  in  On.[  Power  ]  key  is  under  “ ”  On 
status. 
Yes => 3 
No => Please check the [ Power ] key to start power and check whether 
the exception is removed. 
3.  Check whether set power voltage of instrument is larger than the power 
supply voltage. If set power voltage is 220 V and the supply voltage is 110V, 
the power supply cannot start. 
4.  Check whether the fuse of electronic fuse is burned out. 
If yes, change fuse. Detailed steps: 
1)  Pull out power line and take out the fuse box at power line jack with a 
small screw driver. As shown below.