EasyManua.ls Logo

ITech IT8211 - LIST Function: Results and Values; Test Pass;Fail Indication; Cursor Position Step Values

ITech IT8211
15 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Cursor position
Voltage
Stepping values
Current
Stepping values
Resistance
stepping values
10V
Area
Stepping
values
Area
Stepping
values
0-3A 1A
0.1-10Ω 1Ω
10-99Ω 10Ω
0-30A 10A
100-999Ω 100Ω
1000-4000Ω 1000Ω
1V
0-3A 0.1A
0.1-10Ω 0.1Ω
10-99Ω 1Ω
0-30A 1A
100-999Ω 10Ω
1000-4000Ω 100Ω
0.1V
0-3A 0.01A
0.1-10Ω 0.01Ω
10-99Ω 0.1Ω
0-30A 0.1A
100-999Ω 1Ω
1000-4000Ω 10Ω
0.01V
0-3A 0.001A
0.1-10Ω 0.001Ω
10-99Ω 0.01Ω
0-30A 0.01A
100-999Ω 0.1Ω
1000-4000Ω 1Ω
Step value for Cursor Position
A
B
C
D
11) When past the test successfully, the
instrument display as normal; when fail to
pass the test, the instrument will display
as right figure, display wrong step, alarm
3 second and shut the input. Right figure
show the condition the first step not pass.
SV
V
A
IT8211 60V/30A/150W
DC Electronic Load
Prog CC
Short CV
OFF
Shift
30A
CR
ITECH
A
B
C
D
SV
W

Related product manuals