Cursor position
Voltage
Stepping values 
Current 
Stepping values
Resistance 
stepping values 
10V
Area 
Stepping 
values
Area
Stepping
values
0-3A 1A
0.1-10Ω 1Ω
10-99Ω 10Ω
0-30A 10A
100-999Ω 100Ω
1000-4000Ω 1000Ω
1V
0-3A 0.1A
0.1-10Ω 0.1Ω
10-99Ω 1Ω
0-30A 1A
100-999Ω 10Ω
1000-4000Ω 100Ω
0.1V
0-3A 0.01A
0.1-10Ω 0.01Ω
10-99Ω 0.1Ω
0-30A 0.1A
100-999Ω 1Ω
1000-4000Ω 10Ω
0.01V
0-3A 0.001A
0.1-10Ω 0.001Ω
10-99Ω 0.01Ω
0-30A 0.01A
100-999Ω 0.1Ω
1000-4000Ω 1Ω
Step value for Cursor Position
A
B
C
D
11) When past the test successfully, the 
instrument display as normal; when fail to 
pass the test, the instrument will display 
as right figure, display wrong step, alarm 
3 second and shut the input.  Right figure 
show the condition the first step not pass.
SV
V
A
IT8211 60V/30A/150W
DC Electronic Load
Prog CC
Short CV
OFF
Shift
30A
CR
A
B
C
D
SV
W