28
2
th
byte
Address (031,0XFF)
3
th
byte
CommandBCH/BDH
From 4
th
to 7
th
byte
The voltaeg upper limit (Lower bytes are in the former location,
higher bytes are in the later location)
From 8
th
to 25
th
byte
Syetem reserve
26
th
byte
Sum code
57. Set/Enquire the voltage lower limit in CW mode(BEH/BFH)
1
st
byte
Start bit ( AAH )
2
th
byte
Address (031,0XFF)
3
th
byte
CommandBEH/BFH
From 4
th
to 7
th
byte
The voltaeg lower limit (Lower bytes are in the former location,
higher bytes are in the later location)
From 8
th
to 25
th
byte
Syetem reserve
26
th
byte
Sum code
58. Set/Read max input resistance setting of E-load.( C0H/C1H)
1
st
byte
Start bit ( AAH )
2
th
byte
Address (031,0XFF)
3
th
byte
Command(C0H/C1H
From 4
th
to 7
th
byte
max input resistance value(Lower bytes are in the former location,
higher bytes are in the later location)
From 8
th
to 25
th
byte
Syetem reserve
26
th
byte
Sum code
59. Set/Enquire the voltage upper limit in CR mode.( C2H/C3H)
1
st
byte
Start bit ( AAH )
2
th
byte
Address (031,0XFF)
3
th
byte
CommandC2H/C3H
From 4
th
to 7
th
byte
The voltage upper limit (Lower bytes are in the former location,
higher bytes are in the later location)
From 8
th
to 25
th
byte
Syetem reserve
26
th
byte
Sum code
60. Set/Enquire the voltage lower limit in CR mode.( C4H/C5H)
1
st
byte
Start bit ( AAH )
2
th
byte
Address (031,0XFF)
3
th
byte
CommandC4H/C5H
From 4
th
to 7
th
byte
The voltaeg lower limit (Lower bytes are in the former location,
higher bytes are in the later location)