Input Settings
Copyright © ITECH Electronic Co., Ltd. 33
⚫ CURRent: Constant Current Mode
⚫ VOLTage: Constant Voltage Mode
⚫ POWer: Constant Power Mode
⚫ RESistance: Constant Resistance Mode
⚫ DYNamic: Dynamic Operation Mode
⚫ LED: LED Mode
⚫ IMPedance: Constant Impedance Mode
*RST Value
CURRent
Examples
MODE RES
[SOURce:]CURRent[:LEVel][:IMMediate][:AMPLitude]
<NRf+>
This command is used to set the current setting in CC mode.
Command Syntax
[SOURce:]CURRent[:LEVel][:IMMediate][:AMPLitude] <NRf+>
Parameters
MIN~MAX|MINimum|MAXimum
Unit
A
*RST Value
MINimum
Examples
CURR 5
Query Syntax
[SOURce:]CURRent[:LEVel][:IMMediate][:AMPLitude]?
Returned Parameters
<NR2>
[SOURce:]CURRent[:LEVel][:IMMediate][:AMPLitude]?
This command is used to query the current setting in CC mode.
Command Syntax
[SOURce:]CURRent[:LEVel][:IMMediate][:AMPLitude]?