Loading...
Input Settings
Copyright © ITECH Electronic Co., Ltd. 32
[SOURce:]FUNCtion <function>
[SOURce:]MODE <function>
These two commands are equivalent and are used to select the input mode of
the load.
Command Syntax
[SOURce:]FUNCtion <function>
[SOURce:]MODE <function>
Parameters
CURRent | VOLTage | POWer | RESistance | DYNamic | LED | IMPedance
CURRent: Constant Current Mode
VOLTage: Constant Voltage Mode
POWer: Constant Power Mode
RESistance: Constant Resistance Mode
DYNamic: Dynamic Operation Mode
LED: LED Mode
IMPedance: Constant Impedance Mode
*RST Value
CURRent
Examples
MODE RES
Query Syntax
[SOURce:]FUNCtion?
[SOURce:]MODE?
Returned Parameters
<CRD>
[SOURce:]FUNCtion?
[SOURce:]MODE?
These two commands are equivalent and are used to query the input mode of
the load.
Command Syntax
[SOURce:]FUNCtion?
[SOURce:]MODE?
Returned Parameters
CURRent | VOLTage | POWer | RESistance | DYNamic | LED | IMPedance