Basic Operations
Copyright © ITECH Electronic Co., Ltd. 37
6. Press [Enter] to save the setting.
Select one electronic load as the master.
1. Press [Menu] to enter the system menu setting interface.
2. Select [PARALLEL SETUP] to enter the parallel setting interface.
3. Press the Up and Down key to select the “Operating Mode” > “Parallel”.
4. Set “Phase Class” as “Single”.
5. Set Phase/Position” as Master-A(1)”.
6. Set Total Unit as 3.
7. Press [Enter] to save the setting.
After saving the settings, the user must power off three electronic loads and
power on again. The interfaces of master and slave are shown as below.