Programmer's Guide PcOS Series 150 Control Codes
Vertical Motion
12/14/99 Rev G Page 21
Function Set form length in lines
ASCII [ESC] C <n>
Hexadecimal 1BH 43H <n>
Decimal <27> <67> <n>
IPCL &%SL <m
1
> <m
2
>
EPOS [ESC] C <n>
Description This command sets the form length to <n> lines at the current line spacing.
Function Set form length in inches
ASCII [ESC] C [NUL] <n>
Hexadecimal 1BH 43H <0> <n>
Decimal <27> <67> <0> <n>
IPCL &%SI <m
1
> <m
2
>
EPOS none
Description This command sets the form length to <n> inches.
Function Begin auto line feed
ASCII [ESC] 5 <01>
Hexadecimal 1BH 35H 01H
Decimal <27> <53> <01>
IPCL &%MA
EPOS none
Description This command sets auto line feed mode.
Note: This overrides the configuration setting.
Function End auto line feed
ASCII [ESC] 5 <0>
Hexadecimal 1BH 35H 00H
Decimal <27> <53> <0>
IPCL &%CA
EPOS none
Description This command ends auto line feed mode.
Note: This overrides the configuration setting.
Function Reverse line feed
ASCII [ESC] ]
Hexadecimal 1BH 5DH
Decimal <27> <93>
IPCL &%LR
EPOS none
Description This command performs a reverse line feed at the current line spacing.
Note: The receipt station can tolerate no more than 1/2 inch of reverse feed.
Note: This command is not available in models with validation.