8. USER TROUBLESHOOTING GUIDE
8.1. Undercounter models
None of the electrical parts
work.
The machine is unplugged.
Plug in the machine and verify socket power
Bin thermostat open. Ice touching bin
tube.
Bin thermostat open. No ice touching
bin tube.
Adjust thermostat (electric box under top cover)
All the electrical parts work but
not compressor. (water doesn´t
freeze)
Compressor switch is in the “WASH”
position (0).
Switch to “ICE” position (1).
Inlet strain at water valve blocked
Bin full and ice touching
thermostat tube, but machine
doesn´t stop
Bin thermostat doesn´t open (only
operates at harvest time)
Adjust thermostat (electric box under top cover)
Ice slab empty or too thick
Adjust thermostat (electric box under top cover)
Difficult to release ice slab at
harvest
Unit bad leveled (tilted to back)
Add more pins to cam timer wheels (as label
indications)
Not uniform flow pattern at
evaporator
Dirty or scaled distributor
Perform descaling procedure.
Remove and clean distributor (pull from two clips at
distributor sides)
Unit run and stops alternatively
itself
Clean air condenser (behind front grid)
For further problems call aftersales service