SERVICE MANUAL SPIKA
16
re-initiated.
t1
Continuous signal time for water level
5”
t2
Continuous signal time for ice thickness
10”
t3
Open curtain time to activate full storage indication
30”
t4
Start-up timing time
30”
t5
Operation launching maximum time
3.5’
t6
Draining time during operation launching
45”
t7
Production minimum time
5”
t8
Water inlet valve e/w time during production
30”
t9
Water inlet valve e/w timeout
120”
t10
Production maximum timeout
60’
t11
Pump start-up delay time
30”
t12
Draining time at cleaning cycle
60”
t13
Retry time due to water inlet valve e/w timeout
60’
5.2. Control Board