ITW Dynatec c. 2004
DYNAMINI ASU Manual #20-25
Page 2-3
Revised 1/05
Pressurized Air:
Air pressure supply 1.4 to 6.8 bar (20 to 100 psig). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Air consumption at 60 pump cycles per minute 90 normal liters/ minute. . . . . . . . . . . . . . . . . . . . . . .
(3.2 SCFM at 100 psig)
Performance:
Adhesive temperature control range 40°C to 218°C (100°F to 425°F). . . . . . . . . . . . . . . . . . . . . . . . .
Adhesive temperature control accuracy ± 1°C (± 1°F). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Over-temperature cutoff for hopper 232°C (450°F). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Adhesive viscosity 500 to 50,000 centipoise. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Warm-up time, full hopper approximately .5 hour. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Adhesive delivery rate, open line .91 kg/min (2 lb/min)(12:1 piston pump). . . . . . . . . . . . . . . . . . . . .
Adhesive melt rate (depends on adhesive used) 8 kg/hr (17.3 lb/hr). . . . . . . . . . . . . . . . . . . . . . . . . . .
Adhesive pressure up to 68 bar (1000 psi) maximum. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Maximum pump speed, piston pump 60 pump cycles per minute. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Maximum pump speed, gear pump 87 revolutions per minute, 60 Hz, constant speed. . . . . . . . . . . . . .
73 revolutions per minute, 50 Hz, constant speed
Dynamini Temperature Control:
Controller board 1 printed circuit board. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Display type long-life, light-emitting diode (LED). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Temperature control zones 5 triac-output. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Other:
Operator interface digital display with simplified, all-icon keypad. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Temperature offset no. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Sensor open error message yes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .