Overtemp Thermostat
The overtemp thermostat is a safety back-up. If the hopper temperature exceeds 232°C (450°F), the
thermostat causes a circuit breaker to open and power to the hopper and all hoses and heads will be
cut off. The overtemp thermostat re-sets when the hopper temperature falls below 204°C (400°F).
To re-set, turn the main power switch OFF, then ON again.