EasyManua.ls Logo

ITW Dynatec DYNAMINI - Removing the Hopper Lid; Thermostat Replacement Procedure; Overtemp Thermostat Replacement; RTD Sensor Replacement Procedure

ITW Dynatec DYNAMINI
90 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 8-2
Revised 1/05
ITW Dynatec c. 2004
DYNAMINI ASU Manual #20-25
To Remove the Hopper Lid
(See illustration on page 10-7)
1. Remove the four flat head screws which are
located one on each side of the lid base.
2. Pull the lid up to remove.
a.
Lid Seal Replacement:
The lid seal (o-
ring) is located inside the lid base.
1. Remove the old seal, which rests against the
top of the hopper.
2. Install the new seal into the groove pro-
vided.
Thermostat Replacement
(See illustration on pages 10-7.)
1. Remove the access cover screw.
2. Lift the access cover out of its slots in the
base.
Overtemp Thermostat Replacement:
1. Remove the two screws and slip the termi-
nals and the hopper ground wire off of the
thermostat.
2. Remove the thermostat from the base of the
hopper.
3. Install new thermostat with two secrews and
re-install the terminals and hopper ground
wire.
Lid
Lid base
Lid seal
Overtemp
Thermostat
Sensor
RTD Sensor Replacement
(See illustration on page 10-11)
1. Remove the pump and electronics cover. The RTD sensor is centered between the cast-in heat-
ers on the base of the hopper.
2. Slip the sensor out of its adapter.
3. Unplug the sensor wires from pins 1 and 2 on the Control PCB (see PCB illustration on page
7-5).

Table of Contents