ITW Dynatec c. 2004
DYNAMINI ASU Manual #20-25
Page 5-9
Revised 1/05
Error Indication Messages
“EO1” = the temperature sensor is open (no sensor attached) or has
high resistance.
“EO2” = the temperature sensor is shorted or has low resistance.
System Ready Indicator Light
When not in programming mode, a flashing temperature scale light
(LED) indicates that theASU isnot “Ready” forproduction.This LED
will cease to flash when all temperature zones are within the pro-
grammed temperature tolerance window.
Set your Tank setpoint as described earlier in this chapter.
Push and hold the Tank icon. While holding, press the #1 Hose icon. Release.
Push and hold the Tank icon again. While holding, press the #1 Head icon. Release.
The manually programmed setpoint has now been pasted in to all turned on hose and
head zones. When programming is complete, wait a few seconds and the controller
will return to the ASU’s actual temperature.
&
To Copy and Paste Setpoints
The Copy/ Paste feature of the controller copies the tank setpoint and pastes it as the setpoint of
other temperature zones. The paste will apply to only temperature zones that are switched ON.
&
then
Controller Features