5101015-01 Rev 2 9
2.4 Optional Remote Control Connection
The power unit is equipped for remote actuation of airflow and
ionization. If remote actuation is required, the connection must be
done by qualified service personnel. Disconnect line voltage and
compressed air from power unit. Remove cover screws and open
chassis to expose power unit circuit board. Remove the knock-out
plug near the power and air connections. Install an appropriate
strain relief with cable or conduit. The remote control will actuate on
contact closure, the switch or relay must be rated for 100 volts DC
and be isolated from ground. Connect wiring from switch or relay to
the two 1/4" x 0.032" tabs on circuit board (J4 & J5) using insulated
quick disconnects. Close chassis and replace cover screws. Note:
the bi-level LED in the gun will remain at stand-by status when the
remote control is used.
CAUTION! ELECTRICAL SHOCK HAZARD
Conductors carrying AC power line voltage and high voltage
are exposed when covers are off and power is connected.
PRUDENCE! RISQUE DE CHOC ÉLECTRIQUE
Conducteurs transportant AC le courant secteur puissance et
haute tension sont exposés lorsque les couvertures sont
désactivées et la puissance est reliée.
CAUTION! ELECTRICAL SHOCK HAZARD!
Remote control circuit uses approximately 100 VDC.
PRUDENCE! RISQUE DE CHOC ÉLECTRIQUE
Circuit de commande à distance utilise environ 100 VDC.