15
TROUBLESHOOTING / SPECS
TROUBLESHOOTING / SPECS
TROUBLESHOOTING
SPECIFICATIONS
UNIT DOES NOT START
• Make sure the dehumidifier’s plug is secured entirely into
the outlet.
• Check your home fuse/circuit breaker box.
• Dehumidifier has reached its preset level or bucket is full.
• Water bucket is not in the proper position.
DEHUMIDIFIER DOES NOT DRY THE AIR AS IT SHOULD
• Allow enough time to remove the moisture.
• Make sure there are no curtains, blinds or furniture blocking
the front or back of the dehumidifier.
• The humidity control may not be set low enough.
• Check that all doors, windows and other openings are
securely closed.
• Room temperature is too low, below 41°F (5°C).
• There is a kerosene heater or something giving o water
vapor in the room.
THE UNIT MAKES A LOUD NOISE WHEN OPERATING
• The air filter is clogged.
• The unit is tilted instead of upright as it should be.
• The floor surface is not level.
FROST APPEARS ON THE COILS
• This is normal. The dehumidifier has Auto defrost feature.
WATER ON FLOOR
• Hose to connector or hose connection may be loose.
• Intend to use the bucket to collect water, but the rear drain
plug is removed.
ES, AS, P2 AND EC APPEAR IN THE DISPLAY
• These are error codes and protection code. See the
CONTROL BUTTONS section.
Power: 115V~60Hz
Moisture Removal: 50 Pint (64.9°F/60%RH)
Refrigerant: R-410A
Current Consumption: 8.6A
Dimensions: 23.5” x 11.1” x 15.28”
Weight: 41 lbs.
Operating Temperature: 41°F~89.6°F