EasyManuals Logo

Iveco N67 ENT M45 User Manual

Iveco N67 ENT M45
42 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #20 background imageLoading...
Page #20 background image
19
ENGLISH
Operation
When the key switch is turned to position 8B an efficiency test will be
performed on all the indicator lights, lasting 5 seconds, with the
exception of the “Pre-lubrication”, “Pre-post heating”, “EDC electronic
injection system malfunction” indicators, and simultaneously the beeper
sounds; It is possible to stop the beeper before the end of the test, by
pressing the relevant button.
During start-up and for the following 15 seconds, all alarm functions are
disabled; after this period, each alarm detected by the sensors provided
on the engine will result in the relevant indicator flashing and a
simultaneous warning sound from the beeper. If the beeper is disabled
by pressing the relevant button, the indicator light will turn on without
flashing and the alarm will be stored until the engine is stopped.
Alpha-numeric display
This provides the following information:
engine running speed
total running hours (see note A)
exhaust gas temperature (on request)
instant fuel consumption (see note B)
The information required is selected by pressing the “Scroll select
button on both the control panels, main and secondary.
Detail of the main control panel
7. Alpha-numeric display - 9. Accessory function programming button -
10. Button used to scroll through and select additional information -
11. Button to reset the “planned maintenance” indicator - 12. Button
to disable the beeper.
(A)The control panel's internal electronics are programmed to count
the working hours and issue warnings when the time limit for
ordinary maintenance operations expires; this function requires
that the counter be reset after each maintenance operation, which
is carried out from the main control panel as follows:
- Pressing and holding the “Prog” (9) and “Scroll select” buttons (10),
turn the key switch from position 8A to position 8B and wait for
the display to show the pre-set value (e.g: 600 hours). Release the
buttons and press the “Prog” (9) button again once only to start
the new count.
912 11 10
04_360_N
7

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Iveco N67 ENT M45 and is the answer not in the manual?

Iveco N67 ENT M45 Specifications

General IconGeneral
BrandIveco
ModelN67 ENT M45
CategoryEngine
LanguageEnglish

Related product manuals