3. Product Description
3.1 General aspects
The Programat P310 is a modern ceramic furnace for dental applications. The firing chamber may be heated up to max.
1200 °C by means of a heating element. Furthermore, the firing chamber has been designed in such a way that a vacuum
may be created with a vacuum pump. Electronic components with the corresponding software monitor and control the
firing programs. Additionally, the set and actual temperatures are continuously compared.
The Programat P310 consists of the following components:
Furnace base with electronic controls
Furnace head with firing chamber
Cooling tray
Firing table
Power cord and hose for vacuum pump
3.2 Hazardous areas and safety equipment
Description of the hazardous areas of the furnace:
Hazardous area Type of risk
Firing chamber Burn hazard
Opening/closing mechanism Risk of crushing
Electrical components Risk of electrical shock
Description of the safety equipment of the furnace:
Safety equipment Protective effect
Protective conductor Protection from electrical shock
Electrical fuses Protection from electrical shock
Furnace housing and end caps Protection from electrical shock, burning and crushing