6. Practical Use
The operating procedure for the Programat P310 will be explained with the help of two examples: one Ivoclar Vivadent and
one individual program.
6.1 Firing with an Ivoclar Vivadent program
Step 1:
Switch on
Switch on the furnace with the mains switch at the rear of the furnace.
The furnace conducts an automatic self-test.
Wait until the furnace has reached the set stand-by temperature.
Step 2:
Select the program
After the self-test, the display shows the home screen. Press the
[Ivoclar Vivadent Programs] button.
Step 3:
Load the furnace
Open the furnace head with the OPEN FURNACE HEAD key and
place the object on the firing tray in the furnace.
Step 4:
Start the program
Press the START key to start the program. The LED lights up in
green. You can observe the course of the program on the firing
curve display.
The furnace head opens automatically at the end of the program. If
the Optical Status Display (OSD) lights up green, the furnace is ready
for the next program start.
Select the desired program group.
Select the desired program.