EasyManua.ls Logo

IVT Optima 600-1700 - Technical Information

IVT Optima 600-1700
46 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
43
Technical information
Dimensions
Control cabinet (WxDxH) mm 335x112x296
Accessory unit (WxDxH) mm 255x100x180
Control cabinet and accessory unit electric/oil-fi red boiler
Technical information
Output data at +7/35º and +7/45º are stated according to the European standard EN 14511.
1)
Dimensions excl. feet, supplied min 20 mm - max 30 mm depending on adjustment
Model IVT Optima 600 900 1100 1400 1700
Emitted/Supplied output at +7/35º kW 5.5 / 1.4 7.2 / 2.0 8.9 / 2.3 12.9 / 3.3 14.3 / 3.9
Emitted/Supplied output at +7/45º kW 5.1 / 1.7 7.0 / 2.4 8.6 / 2.8 12.5 / 4.0 14.1 / 4.7
Heat carrier fl ow nominal l/s 0.19 0.29 0.34 0.47 0.55
Internal pressure drop heat carrier kPa 5 6 7 7 8
Air fl ow m³/h 2200 2200 2200 5500 5500
Electrical consumption fan A 0.44 0.44 0.44 0.7 (400V N3) 0.7 (400V N3)
Electrical supply 400V 3N~ 50Hz
Fuse size AT 10 16
Compressor Scroll
Highest outgoing heat carrier temperature ºC 65
Refrigerant fi lling R-407C kg 2,5 2,6 2,7 3,4 3,5
HTF connection mm Hose 1 inch internal thread external G25
Defrost system Hot gas with four-way valve
Dimensions (WxDxH)
1)
mm 820x640x1190 920x705x1660
Weight kg 140 145 155 160 165
Colour Champagne
Outer casing Galvanised enamelled plate