Page #54 background image
Page 54 Engine Data Management
NO 2.5V
Calibration error. Return unit to factory.
PWR DWN
Power down the instrument and power up again.
WARNCAL,
WARNCFG
Transient warning messages. If they persistently
occur, return the unit to JPI for repair.
HOBSERR
The time of the most recent flight may not be
reflected in the HOBBS meter.
HOBSBAD
The HOBBS data has been corrupted. The HOBBS
meter will be cleared.
HANGCFG,
HANGCAL
Internal system errors. Return unit to factory.
GPS Interface Diagnostics
Measurements ‘xxx REQ’,
‘xxx RES’ and ‘xxx MPG are all
missing from the scan.
No communications from GPS
receiver to EDM. Possibly no
connection or aircraft GPS is off.
NO - COM message and
‘xxx REQ’, ‘xxx RES’ and
‘xxx MPG’ are all missing from
the scan.
Communications are received by
EDM and the Auto-Protocol setup is
in process. Verify correct output
format setup in GPS receiver; check
GPS connections.
NO - SIG message and
‘xxx REQ’, ‘xxx RES’ and
‘xxx MPG’ are all missing from
the scan.
GPS receiver has insufficient signal
for valid data.
NO - WPT message and
‘xxx REQ’, ‘xxx RES’ are all
missing from the scan.
No waypoints are programmed into
the aircraft GPS receiver.

Other manuals for J.P. Instruments EDM-900

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the J.P. Instruments EDM-900 and is the answer not in the manual?

J.P. Instruments EDM-900 Specifications

General IconGeneral
BrandJ.P. Instruments
ModelEDM-900
CategoryControl Panel
LanguageEnglish