tamper alarm should be triggered.
Technical specifications
Power
3x Alkaline battery, type LR6 (AA) 1.5 V/2.45 Ah
Batteries are not included in the packaging.
Typical lifetime of batteries approx. 2 years
LowBatt state <3,3 V
Quiescent current
consumption
135 μA
Maximum current
consumption
250 mA
Current consumption
during acoustic indication
250 mA
Communication frequency 868,1 MHz, JABLOTRON protocol
Maximum radio-frequency
power (ERP)
<25 mW
Maximal acoustic output 85–88 dB
Type of warning device type W
Dimensions 100 x 67 x 40 mm
Weight (without batteries) 97 g
Classification Security grade 2/Environmental class II (EN 50131-1)
Environment Indoor general
Operating temperature
range
-10 °C do +40 °C
Average operating
humidity
75% RH, without condensation
Certification body Trezor Test (no. 3025)