with the control panel, and the duration is determined by the timer. If you select the option
During the alarm time“ in the timer options, the siren will follow the setting of this
parameter in the control panel, which is a maximum alarm time of 20 min.
Level of volume of supplementary acoustic indication: Low/ Medium*/ Increased/
Highest.
Programmable: ON / OFF* – the slider can be used to set the time range when the acoustic
indication should be increased.
Start of full volume interval: hh:mm – only displayed with Programmable volume.
End of full volume interval: hh:mm – only displayed with Programmable volume.
Optical signalling for section control and warning
When warning: ON / OFF*
When controlling sections: ON / OFF*
Signalling PG
LED indicates sounding PG output: ON / *OFF 1-32
PG output 1-32: No*/ Slow sound signal, 1xOn/2xOff, 20s sound signal, Melody 1,
Melody 2, Melody 3, Melody 4
Siren indication priority
Acoustic alarm indication has the highest priority, followed by system control indication.
Additional system activites have the lowest priority. Indication with higher priority always
bypasses indication with lower priority.
Communication loss
The factory setting is that the siren does not signal a loss of communication with the control
panel. The exception is changing the settings when changing the profile, this is possible
provided, when security level 2 is met. In this case, the siren always signals a loss of
communication with the control panel and this function cannot be turned off.
Battery replacement
System automatically reports when it is necessary to replace the batteries, before
replacement the system must be put into service or maintennace mode, because otherwise a