The asterisk symbol – * indicates the default setting, some parts of which can be changed
when using the F-Link program.
Settings tab
Acoustic indication of alarms from sections
Determines for which section the siren will signal an alarm. The toot is factory set for all
sections.
Reaction: determines whether the siren will sound on the IW* signal (internal alert) or EW
(external alert). An alarm horn is also possible turn off completely (other functions remain).
Siren sound: Intermittent*/Continuous
Maximum siren time [min]: 1, 2, 3*, 4, 5 minutes
Different fire alarm indication: ON / OFF* – determines whether a distinction will be made
between the acoustic interpretation of fire and standard alarm. The interpretation of the
acoustic fire alarm is the same with smoke detectors with an internal siren, i.e. fast.
Other acoustic indication from sections
It determines for which section the siren will signal the other acoustic manifestations. The
toot is factory set for all sections.
During section control: ON / OFF* – if on, the siren will beep when locking 1x, disarming 2x
and disarming after alarm 3x. It only signals for set sections.
During warning: ON / OFF* – if on, the siren responds with three beeps on the impossibility
of securing, in case of unsuccessful one locking and unlocking with alarm memory.
Entry delay: ON / OFF* – if turned on, the siren indicates entry delay setting sections.
Exit delay when partially set: ON / OFF* – if it is on, signals the exit delay of the set
sections at partial security. This option is only available when enabled exit delay when fully
secured.
Exit delay when fully set: ON / OFF* – if it is on, siren signals the exit delay of the set
sections when is set up full security.
Upon loss of communication: ON / OFF* – acoustic signaling is not set by default when
communication is lost. Only when changing the profile depending on meeting the
appropriate security level will it switch to YES* and this setting cannot be turned off. The
siren starts to report the loss of communication by honking after 110 minutes of no contact