9 / 14
P60 Testing speed (r/min)
3700 200-5000
P61 Aging operation time (s)
3 1-255
P62 Special running
0 0-3
0: normal
1: easy sewing
2: initial angle testing
3:automatic testing mode
P63 Aging stopping time (s)
2 1-255
P64 Model selsction
----- -----
P66
Protection switch of machine
head testing
1 0-1
0: Off 1: On
P67
Protection switch of machine
head
1 0-1
P69
Number of consecutive stitches
for upper thread detection
5 0-100
P70
Setting of press foot lift
position of pedal
800 0-4095
P71 Delay time of start sewing
80 0-900
P72
Starting position of pressing
the pedal forward
400 0-4095
P73 End position at low speed
800 0-4095
P74 Max value of pedal analog
4000 0-4095
P75
Setting of pedal back to middle
position
1650 0-4095
P78 Thread clamp ending angle
130 10-359
P79 Thread clamp end angle
320 0-359
P80 Trimming starting angle
0 0-359
P81 Trimming strength angle
100 0-359
P82 Trimming ending angle
180 0-359
P83
Pedal presser foot confirmation
time. (ms)
150 1-500
P84
The confirmation time of
Safety switch alarm (ms)
300 1-500
P85
The recovery time of Safety
switch alarm (ms)
50 1-200
P86
Speed of two slopes at a
turning point. (r/min)
1500 0-4000
P87
Two slope intermediate
simulation
2700 0-4095
P88 Unit of counting
1 1-50
P89 Setting of total counting
9999 1-9999
P90 Counter mode
0 0-6
1: Ascending cycle count.
2: Descending cycle count.
3:Ascending accounting to full, alarm and