4 CONTROLS
en-28
4.2.6.18 FAULT LOG ____________________________________________________________
Navigate to the Service Menu.
Use the UP and DOWN arrow keys until the green arrow is
next to Fault Log. Press the select button to select Fault Log.
The last 50 “Faults” that the controller finds are recorded. When 50 faults are
recorded, the fault that next occurs will write over the oldest fault.
The inclinometer records faults when the mower is operated on slopes greater
than 22°.
The engine controller records the engine shut down faults because of
overheat or loss of oil pressure.
The mower controller records hydraulic by-pass fault and missed service.
Press the button to select, press the UP and DOWN arrow
keys to move the green arrow . The errors will move with the last error at
the top of the screen.
Select the fault log to be accessed and accept to show the details.
These details show the date and time of the fault.
Press the back button to return to previous menu.
402.6 Hours
234.1 Hours
137.5 Hours
Fault Log
1
2
3
Engine Overheat Fault
Date 08/27/2018
Time 2:23 PM
Fault Log
Fault Log
Time Until Service
Vehicle Status
I/O Diagnostics
Inhibit Regen
Parked Regen
Service Menu