J-200 Series
6.0  Power Requirements
Jacuzzi
®
 spas are designed to provide optimum performance and 
exibility of use when connected to the maximum electrical service listed 
below. Minor circuit board modications can be performed to allow your 
new spa to accept an electrical service other than the factory operation 
setting. 
Note: Refer to pages 44-47 for circuit board conguration details or 
contact your authorized Jacuzzi dealer.
All North American J-270 and J-280 Models (60 Hz)
240V/40A* 240V/50A** 240V/60A***
Circuit Breaker (2-Pole): 40A* 50A** 60A***
Number of Wires: 3 3 3
Frequency: 60 Hz 60 Hz 60 Hz
Current Draw: 26A 36A 45A
*
  In 40A conguration, the heater will not operate while either jets 
pump is running in high speed. Note: pump 2 runs only in high 
speed.
**
  In 50A conguration, the heater will not operate while both jets 
pumps are running in high speed. This is the factory setting. 
Note: pump 2 runs only in high speed.
***
  In 60A conguration the heater will operate while both jets pumps 
are running in high speed.
All North American J-230 Models (60 Hz)
240V/40A* 240V/50A**
Circuit Breaker (2-Pole): 40A* 50A**
Number of Wires: 3 3
Frequency: 60 Hz 60 Hz
Current Draw: 26A 36A
*
  In 40A conguration, the heater will not operate while the jets 
pump is running in high speed.
**
  In 50A conguration, the heater will operate while the jets pump is 
running in high speed. This is the factory setting. 
13