INST 396 Jacuzzi® J-HN Series Heater V12-16
RISK OF FIRE OR EXPLOSION FROM INCORRECT FUEL USE
Do not try to operate a pool heater set up for Natural Gas on Propane or the reverse. Only Qualified Gas appliance service
professionals should attempt to convert the heater from one fuel to another with advice and instructions from the manufacture.
Alternately, the heater may require conversion at a factory authorized repair depot. Serious malfunction of the burner can occur
which may result in loss of life. The heater is available for operation on Natural Gas or Propane Gas only it is not designed to
operate on any other fuels. Refer to the nameplate for the type of gas the heater is factory equipped for use with, only use fuel gas
stated on nameplate.
RISK OF FIRE OR EXPLOSION FROM FLAMMABLE VAPORS
Do not store Gasoline (petrol), cleaning fluids, paint, varnishes, or other flammable liquids near or in the same room as the heater
RISK OF EXPLOSION IF HEATER IS INSTALLED NEAR PROPANE STORAGE TANKS
Propane (LPG) gas is heavier than air which causes the gas to settle (pool) in the lowest point of the room. Without dissipating. Any
leaking source is highly dangerous. Consult local codes and fire protection authorities about specific installations requirements and
restrictions. Locate the heater away from propane Gas Storage and filling equipment as specified by the latest editions of the
Standard for Storage and Handling of Liquefied Petroleum Gases, CAN/CSA B149.2, or the National Fuel Gas Code, ANSI
Z223.1/NFPA 54.
RISK OF FIRE, CARBON MONOXIDE POISONING, OR ASPHYXIATION FROM LEAKING
EXHAUST VENT, OR IF INCORRECTLY VENTED.
Only qualified service technicians should attempt to service the heater and/or vent system, as leakage of exhaust flue gases or
flammable gases may result from improper servicing. This heater does not use a draft hood and the exhaust is under positive
pressure from burner fan blower. The heater is supplied with an integral vent system for outdoor installations. A factory vent
conversion kit is available for installations in enclosures (Canada) or indoor installations (USA) use only the specified listed vent pipe
(ducts) and fittings for Category III vents, when the heater is installed in an enclosure or indoors. In Canada, this heater can only be
installed outdoors, or in an enclosure that is not normally occupied and has no openings directly connected (communicating) to
occupied areas, See Venting Section of this manual for more details.